Heavy Duty Oil Mist Exhaust Filters

"HDL" Series 3" MPT - 8" 125 / 150# Pattern Flange




Compact Oil Mist
Exhaust Eliminators
Heavy Duty Oil
Mist Exhaust Filters
Compact Oil Mist Exhaust
Filters w/ Drain Back
Back to Air Filtration

Compact Oil
Mist Exhaust Filters
Air / Oil Separation
Vacuum Pump Separator
Back to Solberg Main
Home


Heavy Duty Oil Mist Exhaust Filters - HDL Series
Applications & Equipment


Heavy Duty Oil Mist Exhaust Filters - HDL Series
  • Vacuum Furnaces & Ovens
  • Vacuum Freeze Drying & Outgassing
  • Custom Vacuum Pumping Systems
  • Vacuum Drying
  • Vacuum Metallizing
  • Vacuum Coating
  • Food Processing & Packaging
  • Medical Industry
  • Industrial Aerosol Scrubbing
  • Pressure Unloading Vents on Piston Compressors
  • Blower Exhaust Oil Mist Removal
  • Applications requiring low delta p Coalescing of Large air volumes
Internal Diagram of Heavy Duty Oil Mist Exhaust Filters - HDL Series


Features & Specifications Options (Inquiries Encouraged)

  • Minimum 99.97% D.O.P. on 0.3 micron particles
  • Captures oil fog, mist or smoke from exhaust of oil flooded vacuum pumps
  • Multiple separation stages in a single element design
  • Pleated filter element provides increased surface area for low back pressure separation of ultra-fine oil mists
  • Large oil holding capacity and easy field maintenance
  • 10 PSIG proof pressure
  • Positive engagement O-ring seal system
  • Rugged all steel construction w / baked white enamel finish
  • 1/2 drain tap standard
  • Temperature (continuous): min 40 F (4.4 C) max 220 F (104 C)
  • Often used in conjunction with existing air / oil separation equipment
  • Filter change out differential: Please refer to Vacuum Pump Manufacturers specifications
  • Available in Stainless Steel
  • Epoxy or Teflon coated housings
  • Available in Stainless Steel
  • Specialty media & gaskets / seals for custom installations / applications
  • Flange adapters
  • For Severe applications contact rep
  • Activated carbon postfilters to reduce odor


Nominal Vacuum Pump Rating
SCFM Element Rating
Approx. Wt. Lbs.
Model Number
Inlet & Outlet
Connection Style
DIMENSIONS - inches
A
B
C
D
E
F
G
HDL-PSG344 / 2-300
3"
MPT
31 1/8
3
14
22 1/2
3
12
15
300
500
75
HDL-PSG344 / 2-400
4"
MPT
31 1/8
3
12
22 1/2
3
12
15
500
500
78
HDL-PSG474 / 2-500
5"
MPT
38 1/8
3
18 1/2
29 1/2
3
16
15
800
1100
160
HDL-PSG474 / 2-600
6"
MPT
39 1/8
4
18 1/2
30 1/2
4
16
22
1100
1100
160
HDL-PSG476-800F
8"
FLG
38 4/5
4
21
25 1/2
4
19
22
1800
1800
180


Compact Heavy Duty Oil Mist Exhaust Filters - HDL Series 1" - 2 1/2" FPT
Applications & Equipment


  • Vacuum Furnaces & Ovens
  • Vacuum Freeze Drying & Outgassing
  • Custom Vacuum Pumping Systems
  • Vacuum Drying
  • Vacuum Metallizing
  • Vacuum Coating
  • Food Processing & Packaging
  • Industrial Vacuum Processes
  • Medical Industry
  • Industrial Aerosol Scrubbing
  • Pressure Unloading Vents on Piston Compressors
  • Blower Exhaust Oil Mist Removal
  • Applications requiring low delta p Coalescing of Large air volumes
Premium Grade Silencer Filters



Features & Specifications Options (Inquiries Encouraged)

  • Minimum 99.97% D.O.P. on 0.3 micron particles
  • Captures oil fog, mist or smoke from exhaust of oil flooded vacuum pumps
  • Pleated filter element provides increased surface area for low back pressure separation of ultra-fine oil mists
  • Large oil holding capacity and easy field maintenance
  • Brazed fittings to protect against leaks
  • Seamless drawn housing-no welds to rust or vibrate apart
  • Positive engagement O-ring seal system
  • Rugged all steel construction w / baked white enamel finish
  • 1/4" drain tap standard
  • Temperature (continuous): min 40 F (4.4 C) max 220 F (104 C)
  • Often used in conjunction with existing air / oil separation equipment
  • Filter change out differential: Please refer to Vacuum Pump Manufacturer's specifications
  • Available in Stainless Steel
  • Epoxy or Teflon coated housings
  • Specialty media & gaskets / seals for custom installations / applications
  • Activated carbon postfilters to reduce odor
  • Special Connections


Nominal Vacuum Pump Rating
SCFM Element Rating
Approx. Wt. Lbs.
Model Number
FPT Inlet & Outlet
DIMENSIONS - inches
A
B
C
D
E
F
G
HDL-PSG848-100HC
1"
6 3/4
3/4
7 5/16
4 5/8
3/4
6 3/4
5 1/4
40
50
5
HDL-PSG848-125HC
1 1/4"
6 3/4
3/4
7 5/16
4 5/8
3/4
6 3/4
5 1/4
50
50
5
HDL-PSG848-150HC
1 1/2"
6 3/4
3/4
7 5/16
4 5/8
3/4
6 3/4
5 1/4
50
50
5
HDL-PSG850/1-200HC
2"
11 1/4
3/4
8 3/4
8 3/4
3/4
7 5/8
9 1/4
125
125
15
HDL-PSG860/1-200HC
2"
17 1/2
3/4
8 3/4
8 3/4
3/4
7 5/8
14 1/2
175
200
30
HDL-PSG850/1-250HC
2 1/2"
11 3/4
1 1/4
8 3/4
8 3/4
1 1/4
7 5/8
9 1/4
125
125
15
HDL-PSG860/1-250HC
2 1/2"
18
1 1/4
8 3/4
8 3/4
1 1/4
7 5/8
14 1/2
200
200
30
HDL-PSG294-250C
2 1/2"
16
2 1/2
15 1/4
15 1/4
2 1/2
12
10
250
300
35





Request Information Home Contact Us


Visit our other sites: jbsystemsusa.com
solventrecoveryusa.com, vacuumpumpusa.com,
water-filtersystems.com, wastewater-filtration.com,
liquidfiltration-products.com
, oilandfuel-filtration.com


© 2011 JB Systems, Inc. | 110 Corporate Park East Drive | LaGrange, GA 30241
(706) 884-3006 | Fax: (706) 884-3067 | Toll Free: 1-800-868-6204
E-Mail: sales@jbsystemsusa.com


Privacy Policy